FEATURES & SPECIFICATIONS
DESCRIPTION:
Biosafety Cabinets are specialized workstations widely used in clinical, pharmaceutical, life science and industrial laboratories where experiments need highly contaminant free environment. Also known as biological safety cabinets and biohazard safety cabinets, these are made in three different class types such as Class 1, Class 2 and Class 3; in which Class 2 is widely used in microbiology laboratories because it provides protection to both product as well as personal. It is biosafety level factor which decides which BSC should be used in laboratory. These cabinets are considered safer than other clean benches because such BSCs effectively eliminate risks to operator / staff, samples and the environment from pathogenic biological agents (PBA) and microorganisms responsible for spreading airborne infection
TYPES:
There are three types of class 2 biosafety cabinets are made. It is the type of work which decides which class 2 BSC should be used in laboratory. Below is short description about all types:
- Type A2: recirculate approximately 70% air and 30% exhaust
- Type B1: recirculate approximately 30% air and 70% exhaust
- Type B2: Does not recirculate but exhaust 100% air
CONSTRUCTION:
These cabinets are ergonomically designed to provide long service life. Only thick metal sheets and pipes are used in construction so that you may get the finest and safest Biosafety Cabinet in the market today. There are three different MOC used.
- Complete Stainless Steel 304 / 316.
- Inner Stainless Steel, Outer Mild Steel.
- Stainless Steel bench, rest mild Steel.
AIR FILTRATION:
In order to minimize spread of airborne bacterial and viral organisms, the use of filter is crucial; therefore, we use HEPA filter 99.99% efficiency for 0.3 micron and ULPA filter 99.999% efficiency for particle size 0.1 microns in our biological class 2 type A2 safety cabinets. These air filters are of reputed brands in the market, economical in price and easy replaceable.
ISO 5 / Class 100 quality, supply and exhaust through HEPA filters are done. Type of air cleaning class limits (air quality) in the working area: ISO 14644-1 and 2 (Class 100). Inflow
velocity remains approx. 105 fpm (0.5 m/sec), while down flow velocity remains approx. 55 fpm (0.3 m/sec). 70 % air is re-circulated and 30% exhaust.
BLOWER:
EBM Papast German blower used in our biosafety cabinet which automatically adjusts the airflow speed without the use of a damper to ensure continuous safe working conditions even without maintenance adjustments.
STANDARD ACCESSORIES:
Our Biosafety cabinets are fitted with fluorescent lights outside working zone. UV lamps are fitted inside working zone in such a way that the operator cannot see them directly. An hour
meter is connected to UV lamp. UV Germicidal tube, Drain outlet with flexible hose, Type of illumination used for working surface: UV tube lights with optical reflectors to ensure uniform
intensity distribution of the UV radiation throughout the cabinet along with white light Electrical sockets are fitted to run any instrument under the working area; in addition, service fixtures for air, gas, vacuum and water are fitted on demand.
We also manufacturer biosafety cabinets class 2 type B1 and B2
SPECIFICATIONS:
Sizes Available | 2ft, 3ft, 4ft, 5ft and 6 ft |
Construction | Epoxy coated CRCA frame |
Work top | Stainless steel 304 |
Direction of air flow | Vertical |
Controller | Microprocessor based controller system Digital display of real time inflow / down flow air velocities, ON/Off switches for Cabinet, Light & Blower |
Intensity of light | 900 Lux |
Air filtration | HEPA filter 99.99% efficiency for 0.3 micron ULPA filter 99.999% efficiency for particle size 0.1 microns |
Air recirculation | 70% recirculation and 30% exhaust |
Average Airflow Velocity | Air flow velocity 450 Cubic foot per min |
Front door | Clear, toughened sliding door of 5mm thickness |
UV exposure time (in min) | 5-10 |
Noise level | Less than 60 decibel |
Power supply in VAC, Hz | 100-240, 50-60 |
Standard fittings | Pressure monitoring system with pressure drop: 13-14 mm Hg pre filter Gas burner Fluorescent lamp UV light With separate switch Taps for vacuum, water and non-combustible gas |
Optional | LCD Display Alarm for variation in air flow and blocked blower Sash height alarm UV hour meter Virus burnout In-built fumigation port Service valves (gas, vacuum, air & water) Electrical sockets Differential pressure sensor Arm / elbow rest Drain outlet with flexible hose Movable stand (wheels) Foot rest Calibration certificates HMI Controller |
Standard Size/ Dimension
IG-CIIA2222 | 2 x 2 x 2 | 610 x 610 x 610 mm |
IG-CIIA2322 | 3 x 2 x 2 | 914 x 610 x 610 mm |
IG-CIIA2422 | 4 x 2 x 2 | 1219 x 610 x 610 mm |
IG-CIIA2522 | 5 x 2 x 2 | 1524 x 610 x 610 mm |
IG-CIIA2622 | 6 x 2 x 2 | 1829 x 610 x 610 mm |
Customize options are available.